; Filename: MART0C29.GSD ; Function: GSD-File for DMS50, Measuring Amplifier DMS ; Revision: 1.0 ; Manufacturer: Martens Elektronik GmbH ; Tel: ++49 40 67073 0 ; Copyright: Martens Elektronik GmbH 2007 #Profibus_DP GSD_Revision = 3 Vendor_Name = "Martens Elektronik GmbH"; Model_Name = "DMS50"; Ident_Number = 0x0C29 Slave_Family = 3@Martens-Elektronik@DMS Revision = "Profile 1.0" Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "DMS2.0_B2.0" Software_Release = "DMS1.2_B0.0" 9.6_supp = 1 MaxTsdr_9.6 = 60 19.2_supp = 1 MaxTsdr_19.2 = 60 93.75_supp = 1 MaxTsdr_93.75 = 60 187.5_supp = 1 MaxTsdr_187.5 = 60 500_supp = 1 MaxTsdr_500 = 100 1.5M_supp = 1 MaxTsdr_1.5M = 150 3M_supp = 1 MaxTsdr_3M = 250 6M_supp = 1 MaxTsdr_6M = 450 12M_supp = 1 MaxTsdr_12M = 800 Repeater_Ctrl_Sig = 0 Implementation_Type = "VPC3" ; oder SPC4 ;Bitmap_Device = "" ;Bitmap_Diag = "" ;Bitmap_SF = "" ;*************************************************************************** ;** Slave spezifische Daten ** ;*************************************************************************** Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Auto_Baud_supp = 1 ; automatic Baudrate Search not supported Set_Slave_Add_supp = 1 ; SetSlaveAdr supported Min_Slave_Intervall = 6 ;100 ; in 100 us für Profibus PA ;*************************************************************************** ;** User spezifische Parametrier-Daten ** ;*************************************************************************** User_Prm_Data_Len = 3 User_Prm_Data = 0,0,0 ; DPV1 related keywords DPV1_Slave = 1 DPV1_Data_Types = 0 Check_Cfg_Mode = 1 C1_Read_Write_supp = 1 C1_Max_Data_Len = 32 C1_Response_Timeout = 100 ;1000 ms C2_Read_Write_supp = 1 C2_Max_Data_Len = 48 C2_Response_Timeout = 100 ;1000 ms C2_Max_Count_Channels = 2 Max_Initiate_PDU_Length = 52 ;*************************************************************************** ;** Modular Station ** ;*************************************************************************** Modular_Station = 1 Max_Module = 1 Max_Input_Len = 18 Max_Output_Len = 0 Max_Data_Len = 18 Max_Diag_Data_Len = 16 Module ="Display Value" 0x42, 0x84, 0x08, 0x05 1 EndModule Module ="Display + Input Value" 0x44, 0x89, 0x08, 0x05, 0x08, 0x05 2 EndModule Module ="Display + Input + MinMax Value" 0x46, 0x91, 0x08, 0x05, 0x08, 0x05, 0x08, 0x08 3 EndModule